@ -45,29 +45,30 @@ type pingvinRegister struct {
|
|||
}
|
||||
|
||||
type pingvinVentInfo struct {
|
||||
SupplyHeated int `json:"supply_heated"`
|
||||
SupplyHrc int `json:"supply_hrc"`
|
||||
SupplyIntake int `json:"supply_intake"`
|
||||
SupplyIntake24h int `json:"supply_intake_24h"`
|
||||
SupplyHum int `json:"supply_hum"`
|
||||
ExtractIntake int `json:"extract_intake"`
|
||||
ExtractHrc int `json:"extract_hrc"`
|
||||
ExtractHum int `json:"extract_hum"`
|
||||
ExtractHum48h int `json:"extract_hum_48h"`
|
||||
Roomtemp1 int `json:"room_temp1"` // Room temperature at panel 1
|
||||
SupplyHeated int `json:"supply_heated"` // Temperature of supply air after heating
|
||||
SupplyHrc int `json:"supply_hrc"` // Temperature of supply air after heat recovery
|
||||
SupplyIntake int `json:"supply_intake"` // Temperature of outside air at device
|
||||
SupplyIntake24h int `json:"supply_intake_24h"` // 24h avg of outside air humidity
|
||||
SupplyHum int `json:"supply_hum"` // Supply air humidity
|
||||
ExtractIntake int `json:"extract_intake"` // Temperature of extract air
|
||||
ExtractHrc int `json:"extract_hrc"` // Temperature of extract air after heat recovery
|
||||
ExtractHum int `json:"extract_hum"` // Relative humidity of extract air
|
||||
ExtractHum48h int `json:"extract_hum_48h"` // 48h avg extract air humidity
|
||||
}
|
||||
|
||||
type pingvinStatus struct {
|
||||
HeaterPct int `json:"heater_pct"`
|
||||
HrcPct int `json:"hrc_pct"`
|
||||
TempSetting int `json:"temp_setting"`
|
||||
FanPct int `json:"fan_pct"`
|
||||
VentInfo pingvinVentInfo `json:"vent_info"`
|
||||
HrcEffIn int `json:"hrc_efficiency_in"`
|
||||
HrcEffEx int `json:"hrc_efficiency_ex"`
|
||||
OpMode string `json:"op_mode"`
|
||||
DaysUntilService int `json:"days_until_service"`
|
||||
Uptime string `json:"uptime"`
|
||||
SystemTime string `json:"system_time"`
|
||||
HeaterPct int `json:"heater_pct"` // After heater valve position
|
||||
HrcPct int `json:"hrc_pct"` // Heat recovery turn speed
|
||||
TempSetting int `json:"temp_setting"` // Requested room temperature
|
||||
FanPct int `json:"fan_pct"` // Circulation fan setting
|
||||
VentInfo pingvinVentInfo `json:"vent_info"` // Measurements
|
||||
HrcEffIn int `json:"hrc_efficiency_in"` // Calculated HRC efficiency, intake
|
||||
HrcEffEx int `json:"hrc_efficiency_ex"` // Calculated HRC efficiency, extract
|
||||
OpMode string `json:"op_mode"` // Current operating mode, text representation
|
||||
DaysUntilService int `json:"days_until_service"` // Days until next filter service
|
||||
Uptime string `json:"uptime"` // Unit uptime
|
||||
SystemTime string `json:"system_time"` // Time and date in unit
|
||||
}
|
||||
|
||||
func newCoil(address string, symbol string, description string) pingvinCoil {
|
||||
|
@ -268,6 +269,7 @@ func (p *PingvinKL) populateStatus() {
|
|||
}
|
||||
p.Status.TempSetting = p.Registers[135].Value / p.Registers[135].Multiplier
|
||||
p.Status.FanPct = p.Registers[774].Value / p.Registers[774].Multiplier
|
||||
p.Status.VentInfo.Roomtemp1 = p.Registers[1].Value / p.Registers[1].Multiplier
|
||||
p.Status.VentInfo.SupplyHeated = p.Registers[8].Value / p.Registers[8].Multiplier
|
||||
p.Status.VentInfo.SupplyHrc = p.Registers[7].Value / p.Registers[7].Multiplier
|
||||
p.Status.VentInfo.SupplyIntake = p.Registers[6].Value / p.Registers[6].Multiplier
|
||||
|
|