# Enervent-control
2023-02-08 20:45:27 +02:00
External control of an Enervent Pingvin
Kotilämpö residential heating/ventilation
2023-01-15 13:15:05 +02:00
unit via RS485 bus using the Modbus protocol.
2023-03-30 14:57:57 +03:00
Provides a REST API for integration into Home Assistant,
with measurements and basic control over Pingvin functions.
2023-03-28 22:16:36 +03:00
2023-03-30 14:57:57 +03:00
Template YAML configurations for Home Assistant are included
in the `homeassistant` folder, intended to be simple to copy-paste
into Home Assistant's `configuration.yaml` with minimal necessary
2023-03-30 15:21:59 +03:00
modifications. These include sensor configurations, helpers and automations for button functions
2023-03-30 15:23:26 +03:00
and a ready made basic dashboard. No custom components are necessary.
2023-03-30 15:21:59 +03:00
![image](https://user-images.githubusercontent.com/50285623/228834067-503f9820-292c-4614-9316-6cec683e89ef.png)
2023-01-15 13:15:05 +02:00
2023-02-08 20:45:27 +02:00
The daemon is designed to run on a Linux host
that has some sort of RS-485 connector attached.
For development a RPi Zero W 1 with a
2023-02-08 20:45:27 +02:00
connected [Zihatec RS 485 HAT](https://www.hwhardsoft.de/english/projects/rs485-shield/?mobile=1)
2023-03-30 14:57:57 +03:00
has been used.
### Building
- clone or download the repo
- Build for the correct architecture, e.g. for Linux 32-bit ARM (Rpi Zero W 1):
```
cd /path/to/repo
env GOOS=linux GOARCH=arm go build -o BUILD/enervent-ctrl-linux-arm32
```
### Configuration:
- CLI flags:
```
-cert string
2023-10-09 21:39:12 +03:00
Path to SSL public key to use for HTTPS (default "~/.config/enervent-ctrl/certificate.pem")
2023-03-30 14:57:57 +03:00
-debug
2023-10-09 21:39:12 +03:00
Enable debug logging
-disable-auth
Disable HTTP basic authentication (default true)
2023-03-30 14:57:57 +03:00
-enable-metrics
2023-10-09 21:39:12 +03:00
Enable the built-in Prometheus exporter (default true)
2023-03-30 14:57:57 +03:00
-httplog
2023-10-09 21:39:12 +03:00
Enable HTTP access logging
2023-03-30 14:57:57 +03:00
-interval int
2023-10-09 21:39:12 +03:00
Set the interval of background updates (default 4)
2023-03-30 14:57:57 +03:00
-key string
2023-10-09 21:39:12 +03:00
Path to SSL private key to use for HTTPS (default "~/.config/enervent-ctrl/privatekey.pem")
2023-03-30 14:57:57 +03:00
-logfile string
2023-10-09 21:39:12 +03:00
Path to log file. Default is empty string, log to stdout
2023-03-30 14:57:57 +03:00
-password string
2023-10-09 21:39:12 +03:00
Password for HTTP Basic Authentication (default "enervent")
-read-only
Read only mode, no writes to device are allowed
2023-03-30 14:57:57 +03:00
-regenerate-certs ~/.config/enervent-ctrl/server.crt
2023-10-09 21:39:12 +03:00
Generate a new SSL certificate. A new one is generated on startup as ~/.config/enervent-ctrl/server.crt if it doesn't exist.
2023-03-30 14:57:57 +03:00
-serial string
2023-10-09 21:39:12 +03:00
Path to serial console for RS-485 connection. Defaults to /dev/ttyS0 (default "/dev/ttyS0")
2023-03-30 14:57:57 +03:00
-username string
2023-10-09 21:39:12 +03:00
Username for HTTP Basic Authentication (default "pingvin")
2023-03-30 14:57:57 +03:00
```
On first run, the daemon generates `~/.config/enervent-ctrl/configuration.yaml` with default values.
2024-03-07 21:20:40 +02:00
Configuration options are the same as with CLI flags. CLI flags take precedence over the config file.
2023-03-30 14:57:57 +03:00
- `serial_address:` Path to RS-485 serial device
- `port:` TCP port for the REST API to listen on
- `ssl_certificate:` Path to SSL certificate for HTTPS
- `ssl_privatekey:` Path to SSL private key for HTTPS
- `username:` Username for REST API HTTP Basic Auth
- `password:` Password for REST API HTTP Basic Auth
- `interval:` Interval of background updates from Modbus
- `enable_metrics:` Enable the built-in Prometheus exporter
- `log_file:` Path to log file, default logging is to STDOUT
- `log_access:` Enable HTTP Access logging to logfile/STDOUT
- `debug:` Enable debug logging
2023-03-30 15:41:34 +03:00
### Running
- Upload the built executable along with `coils.csv` and `registers.csv` to the target host. The files should
be placed in the same folder.
- Run the binary as a regular user. Adding the user to the correct group for serial access may be necessary
- To run persistently, you can use `screen`, `tmux`, or generate a user systemd service unit file.
- Example systemd service file (named e.g. enervent-ctrl.service):
```
[Unit]
Description=Enervent-ctrl
After=network-online.target
[Service]
Type=simple
Restart=on-failure
RestartSec=30
ExecStart=/path/to/enervent-ctrl-executable
[Install]
WantedBy=default.target
```
- Replace paths in the file and place it under `~/.config/systemd/user`. Create the folder if it doesn't exist.
- `systemctl --user daemon-reload`
- `systemctl --user enable --now enervent-ctrl.service`
- To let user services continue running after logging out:
- `sudo loginctl enable-linger $USER`
2023-04-04 22:40:50 +03:00
***
# Disclaimer:
**I am not responsible of possible damage to your device if you choose to follow these instructions**
**The manufacturer may void your warranty if you choose to follow these instructions**
***
### Connecting to the Pingvin unit
2023-04-04 22:40:50 +03:00
#### RPi/computer running the daemon
- Connect an RS-485 adapter to the computer you intend to run the daemon on
- Tested on:
- RPi 4B and Zero W 1, generic x86_64 linux machines (Alma Linux 8 & 9, Fedora)
- Zihatec RS-485 HAT with the Pis
- generic USB-RS485 adapter (checksum errors considerably more often, but nothing critical)
2023-04-04 22:21:25 +03:00
- Ensure the user you intend to run the daemon as has read/write privileges to the serial device.
- **Not recommended and no need to run as root**
- Usually adding the user running the executable to the `dialout` group gives permissions to serial devices
2023-04-04 22:40:50 +03:00
#### Pingvin
- Shut down the main power of the unit
- Disconnect the device from mains, discharge any static electricity before proceeding
- A new motherboard seems to cost close to 1000€ + labour
- Open the cover in which the power switch is attached to. No need to disconnect the switch, there
should be enough length in the wires to move the lid with the switch connected out of the way
2023-04-04 22:21:25 +03:00
![IMG_20230114_133625](https://user-images.githubusercontent.com/50285623/229897490-33d917be-9dea-4b74-bfed-c7b25f9f45f6.jpg)
2023-04-04 22:11:45 +03:00
- Locate the green RS-485 connector on the motherboard, should be on the right edge
- Schematics available from Enervent at [https://doc.enervent.com/op/op.ViewOnline.php?documentid=940&version=1](https://doc.enervent.com/op/op.ViewOnline.php?documentid=940&version=1), page 38 (finnish)
2023-04-04 22:21:25 +03:00
![IMG_20230114_133824](https://user-images.githubusercontent.com/50285623/229898136-ce7dc020-6c33-4605-86ff-5285000cbbd2.jpg)
2023-04-04 22:40:50 +03:00
- There should be available outlet holes to pass the wires through on the top of the electronics compartment.
- The connector has a detachable plug part. Grab the top of the connector (the part with the screws) with plyers and carefully pull it out. This will make attaching the wire much easier
2023-04-04 22:21:25 +03:00
- Attach wires by tightening the screws in the connector
2023-04-04 22:11:45 +03:00
- Connect **A connector to A connector and B to B**. (they are not Tx/Rx like in many other serials)
- **NOTE:** After reading quite a few forum posts, many RS-485 adapters seem to have printed the A and B the wrong way, I wouldn't be surprised if this was the case with Pingvin too.
2023-04-04 22:40:50 +03:00
![IMG_20230114_133936](https://user-images.githubusercontent.com/50285623/229900176-5bac0027-80c6-4702-ab74-0ff2b9739507.jpg)
2023-04-04 22:11:45 +03:00
- Plug the plug back to the Pingvin motherboard and close the cover and screws
2023-04-04 22:40:50 +03:00
![IMG_20230114_135258](https://user-images.githubusercontent.com/50285623/229899975-45126a64-7344-4ca0-bfba-c4e524ebe2f8.jpg)
- Reconnect mains and switch both devices on
- Mixing A and B should be safe and won't break anything, but the daemon won't work. If that's the case, disconnect power again and switch the wires on the RPi end.
2023-04-04 22:11:45 +03:00
### Home Assistant
- There are so many variations for HASS configs, that definite instructions are hard to do.
- All the YAMLs are intended to be copy-pasted to `configuration.yaml` (or files included to configuration.yaml)
- Contents of `homeassistant/automations.yaml` to automations.yaml in your HA `config/` folder
- Contents of `homeassistant/homeassistant-rest.yaml` and `homeassistant/helpers.yaml` to configuration.yaml in your HA `config/` folder
- Replace IP_ADDRESS with the correct IP address, for example with sed: `sed -i 's/IP_ADDRESS/192.168.4.5/g' configuration.yaml`
- If you set a different port for enervent-ctrl, use `sed -i 's/IP_ADDRESS:8888/192.168.4.5:9999/g' configuration.yaml`
- Dashboard:
- create an empty dashboard
- opening the YAML editor in the HA Lovelace UI
- copy the contents from `homeassistant/dashboard-en/fi.yaml` to the editor as-is.
2023-04-04 22:11:45 +03:00
- Change the IP address, port, username and password according to your configuration
- Restart Home Assistant (A full reload doesn't seem to be enough for all REST integration features to update)
2023-03-30 14:57:57 +03:00
2023-03-30 15:42:45 +03:00
Work is part of my Bachelor's Thesis at Oulu University
2023-03-30 14:57:57 +03:00
of Applied Sciences.
Pingvin and Kotilämpö are registered trademarks of Enervent Zehnder Oy.
2024-07-03 14:21:01 +03:00
2024-07-03 14:28:54 +03:00
<sup><sub>Github is used to build the binaries and container images with Github Actions, and host pre-built releases.
2024-07-03 14:21:01 +03:00
Mirrored from https://git.oranki.net/jarno/enervent-ctrl</sub></sup>